Tripp Lite series SmartOnline 5000VA 4500W 120/208V Online Double-Conversion UPS - L6-30P, 18x 5-20R, 2 L6-20R, 1 L6-30R Outlets, Network Card, Maintenance Bypass, Extended Run, 6U Rack/Tower
Product Name |
Eaton Tripp Lite series SmartOnline UPS
|
Catalog Number |
SU5000RTFMB
|
UPC |
037332286369
|
Product Length/Depth |
34 in
|
Product Height |
10.2 in
|
Product Width |
17.3 in
|
Product Weight |
206.1 lb
|
Compliances |
FCC Class A
CE Marked FCC Compliant RoHS ENERGY STAR certified REACH |
Certifications |
IEC/EN 62040-2
NOM CSA 22.2 cTUVus UL 1778 |
Topology |
Online/Double-conversion
|
Form factor |
Rack/tower
|
Rack size |
6U
|
Color |
Black
|
VA rating |
5000 VA
|
Wattage |
4500 W
|
Rack mounting kit |
Yes
|
Package contents |
|
Surge protection |
Yes
|
Internal bypass |
Yes
|
Current Crest Ratio |
3:1
|
Input connection |
Hardwire; L6-30P
|
Input cord length |
10 ft
|
Input nominal voltage |
208V default (200/208/220/230/240V)
|
Nominal frequency |
50/60 Hz
|
Input frequency range |
50/60 Hz
|
Input power factor |
>0.99 typical
|
Receptacle |
(18) 5-20R; (1) Hardwire (200-240V); (2) L6-20R; (1) L6-30R
|
Number of Outputs 5-20R |
18
|
Number of Outputs L6-20R |
2
|
Number of Outputs L6-30R |
1
|
Number of outputs hardwired |
1
|
Output waveform |
True sine wave
|
Voltage |
120/208V
|
Output nominal voltage |
120/240V default (200/208/220/230/240V)
|
Electric current - max |
23.3A
|
Runtime graph |
|
Battery replacement |
EBP-1803
|
Battery type |
Valve Regulated Lead Acid (VRLA)
|
Extended battery capability |
Add up to 4 extended battery modules (EBM). Part number BP180RT
|
Standard factory warranty |
|
Extended service plans |
|
Runtime at half load |
11 min
|
Ethernet interface |
Yes
|
Includes network card |
Yes
|
Software compatibility |
PowerAlert
|
Altitude |
<1000m for nominal power, 10% power degrading every 1000m (up to 3000m)
|
Noise level |
<45 dB at 1 meter
|
Relative humidity |
0-95% non-condensing
|
Temperature range |
0° to 40°C (32° to 104°F)
|
Front Panel LCD Display |
LCD display
|
Input Plug Type |
NEMA L6-30P
|
Output Receptacles |
5-20R
Hardwire (200-240V) L6-20R L6-30R |
Output Receptacles Details |
Hardwire output: 200-240V
|
Input Nominal Voltage |
200 VAC
208 VAC 220 VAC 230 VAC 240 VAC Factory configured to 208V |
Product Features |
Expandable Runtime
Emergency Power Off (EPO)/Remote On-Off (ROO) L6-30P 10ft. |
Product Highlights |
Keeps equipment running during outages to allow time for file saves and safe shutdown
Pre-installed WEBCARDLXE network card enables full remote access and control Stepdown transformer converts 208V input into 120V output for low-voltage equipment Included bypass switch allows uninterrupted operation during UPS maintenance Optional extended battery modules allow extended runtime to keep equipment powered |
PowerAlert Software |
For local monitoring via the UPS’s built-in communication ports, download PowerAlert software at https://tripplite.eaton.com/products/power-alert
|
Nominal Output Voltage |
120V
200V 208V 220V 230V 240V |
Network Management Cards |
WEBCARDLXE
|
Network Management Cards Details |
Network management card included
|
Efficiency at max. load |
93%
|
Input voltage range |
200-240V
|
Max number of battery packs |
4
|
Output frequency |
50/60 Hz
|
Output power factor |
0.9
|
Phase (input) |
Single-phase
|
Runtime at full load |
3 min. (4500W)
|
Communication interface |
Contact closure
Included network card RS-232 USB USB and DB9 serial cables included |
Battery Access |
Battery access door
|
Typical Battery Runtime |
Expandable runtime
|
Expandable Runtime Description |
Add up to 4 extended battery modules (EBM). Part number BP180RT
|
Dc Voltage |
180
|
Operating Temperature Range |
32° to 104°F (0° to 40°C)
|
Communications Cable |
USB and DB9 serial cables included
|
Input Circuit Breakers |
Recommended 30A upstream
|
Installation Form Factor Notes |
Listed 34" depth includes maintenance bypass installed on the back of the UPS power module. Alternate maintenance bypass installation options are available for short rack depth needs. Relocating the maintenance bypass decreases the unit depth to 27.03".
|
Output Circuit Breakers |
20A breaker protects L6-20R and 5-20R outlets
|
High Voltage Transfer to Battery Power |
276V
|
Low Voltage Transfer to Battery Power |
176V
|
Application |
Mission Critical Applications
|
Switch configuration |
RPO / ROO / MBP
|
Housing material |
Metal
|
Output AC waveform (AC mode) |
Pure Sine wave
|
Output AC waveform (battery mode) |
Pure Sine wave
|
Output Capacity (kVA) |
5
|
Output Capacity (kW) |
4.5
|
Output Capacity (VA) |
5000
|
Output Capacity (Watts) |
4500
|
Operating Elevation |
<1,000 meters for nominal power; 10% power derating every 1000 meters (up to 3000 meters) at 40°C
|
AC Suppression Response Time |
0 ms
|
Alarm Interface |
Press ESC to silence the alarm
|
Audible Alarms |
Audible alarm indicates utility failure, low-battery, overload, other UPS/Battery fault or remote shutdown conditions
|
Battery Start Capability |
Cold-start operation supported
|
Cooling Method |
Fan
|
Battery Replacement Description |
Hot-swappable, user replaceable batteries. UPS requires 1 Replacement Battery Cartridge.
|
LED Indicators |
4 status-indicating LEDs
|
Frequency Rating Details |
50 or 60Hz, autosensing or configurable as a frequency converter
|
Minimum Required Rack Depth With External Battery Pack |
31
|
Output Voltage Regulation (Line Mode) |
+/- 1%
|
Output Voltage Regulation(Battery Mode) |
+/- 1%
|
Recommended Electrical Service |
30A
|
Included Mounting Accessory Description |
Includes 4 post rackmount and tower pedestal accessories
|
Input Nominal Voltage Description |
Factory configured to 208V
|
Network Monitoring Port Description |
WEBCARDLXE Supports detailed monitoring of UPS and site power conditions; DB9 port supports RS232 and contact closure communications; not compatible with WEBCARDLX
|
Nominal Voltage Details |
100V, 110V, 120V, 200V, 208V, 220V, 230V, 240V
|
Voltage Regulation Description |
Online, double-conversion power conditioning
|
Plug Type |
L6-30P 10ft.
|
Maximum Input Amps |
23
|
Minimum Required Rack Depth (cm) |
78.74
|
Minimum Required Rack Depth (inches) |
31
|
Total Harmonic Distortion |
< 2% THDV on linear load; < 5% THDV on non-linear load
|
UPS Input Cord Length (m) |
3.1
|
Power Mode Transfer Time |
0 ms
|
Connected Equipment Insurance |
$250,000 Ultimate Lifetime Insurance
|
Optional Accessories |
2 post rackmount (RK2PC)
|
EMI AC Noise Suppression |
EMI / RFI AC Noise Suppression
|
UPS Input Connection Type |
Hardwire
L6-30P |
External Battery Pack Compatibility |
BP180RT
|
Green Energy-Saving Features |
High efficiency economy mode operation
|
High Availability UPS Features |
Automatic voltage regulation (AVR)
Expandable battery backup Hot swappable batteries On-Line/Double-Conversion Pure sine wave output Remote management Surge/noise protection Zero transfer time |